| Requirements | Standard | Description | DRYflex 1 | |||
|---|---|---|---|---|---|---|
| Basic requirements | EN1504-5 table 3C |
U(S2) = | Expected use - concrete waterproofing injections | Compliant | ||
| W(1) = | Minimum crack thickness, 0.1 mm | |||||
| (1/2/3/4) = | May be injected in dry, damp, wet and full of water cracks | |||||
| (5/40) = | Temperature of utilisation 5-40°C | |||||
| Impermeability to water | EN 14068 | at 2x105 and 7x105 Pa | Compliant | |||
| Viscosity | EN ISO 3219 | 20-30 mPa.s | Compliant | |||
| Reactivity | EN ISO 9514 | Gelling time between 10 sec and 30 min. | Compliant | |||
| Durability, dilatation and expansion | EN 14498 | Expansion must reach a constant level < 35%, in accordance with standard EN 14498 – state of conditioning A |
Compliant | |||
| Sensitivity to cycles | EN 14498 | No modification of the expansion rate | Compliant | |||
| Compatibility with cement | EN 12637-1 | Variation of the resistance properties ≤ 20% | Compliant | |||
| Behaviour to corrosion | EN 1504-5 table 3C |
Without corrosive effects | Compliant | |||
| Behaviour to fire | BS6853 | Smoke emission <0.005 m2/g in accordance with BS6853: 1999 Annex D8.3 |
Compliant | |||
| BS EN ISO 4589-2 | Inflammability: oxygen index >90, in accordance with BS EN ISO 4589-2: 1996: Part 2 |
|||||
| Compatibility with drinking water | BS 6920-1: 2000 | Smell and taste of the water: | < 1 | Compliant | ||
| Aspect of the water: | Colour < 0,6 | |||||
| Turbidity: | < 0,09 | |||||
| Presence of micro-organisms: | < 0,4 mg/l |
|||||
| Content of harmful substances to public health morphology of cells: | Satisfactory | |||||
| Colour of culture media: | Normal | |||||
| Single-layer confluence: | 100% | |||||
| Release of metals: | compliant with the standard |
|||||
| Toxicity | VwVws 17/5/1999 |
Class of danger for the waters: | (WGK) 1 (1 = low risk; 5 = high risk) |
Compliant | ||
| Toxicity mammals LD50: | > 2000 mg/kg | |||||
| Aquatic toxicity EC: | > 1000 mg/kg | |||||
| Biodegradability: | Biodegradable in accordance with OECD 301 B |
|||||
| Bio-accumulativity: | Non bio-accumulative | |||||
| DRYflex resin has been subjected to conformity tests by independent EU recognised institutes. A full copy of the certificates can be requested from Drytech SA, Bedano, Switzerland +41 (0)91 960 23 40 |
||||||